image description

Green Air Products Inc.

Hydro Organics (Earth Juice)

5 Item(s)

per page

Grid  List 

Set Descending Direction
  • CD-36LP Generator, Liquid Propane

    Carbon dioxide generators operate by burning carbonaceous fuels such as propane or natural gas. The burners used in Green Air Products CO2 generators are specially designed to maximize the production of CO2 and minimize heat as a by-product. Green Air Products generators provide CO2 far more economically than any other means of enrichment. Carbon dioxide enrichment equipment and methods have improved as experience and the understanding of atmospheric control and plant physiology have advanced. Plant metabolism and growth rate are dependent on the available atmospheric CO2. Plants are keenly sensitive to CO2 variations; optimum values must be constant and precisely controlled. The method, timing, and size of equipment must be properly determined to provide maximum benefits and economy. Carefully follow the operation charts to choose the proper size generator for the cubic foot area. Keep the recharge times to a minimum for best results. Do not undersize the generator or optimum results may never be achieved. Operates on 110 VAC.

    SKU:
    GACD36LP

    Retail: $749.00

    Special Price: $515.78

  • CD-36NG Generator, Natural Gas

    Carbon dioxide generators operate by burning carbonaceous fuels such as propane or natural gas. The burners used in Green Air Products CO2 generators are specially designed to maximize the production of CO2 and minimize heat as a by-product. Green Air Products generators provide CO2 far more economically than any other means of enrichment. A constant burning pilot is used to ignite the gas when the generator is turned on. A thermocouple is used to monitor the pilot flame. If the pilot flame is lost, a safety valve will close so that unburned fuel will not be released into the enclosure. CO2 Generator operations may be automatically functioned according to actual ambient values when installed in conjunction with the CDMC. This control device continually samples the level of carbon dioxide in the growing area and functions the generator whenever CO2 levels do not meet your predetermined values. Generators are easily installed, dependable and efficient. Transformer included. Operates on 110 VAC.
    SKU:
    GACD36NG

    Retail: $749.00

    Special Price: $524.30

  • CD-6LP Generator, Liquid Propane

    Carbon dioxide generators operate by burning carbonaceous fuels such as propane or natural gas. The burners used in Green Air Products CO2 generators are specially designed to maximize the production of CO2 and minimize heat as a by-product. Green Air Products generators provide CO2 far more economically than any other means of enrichment. Carbon dioxide enrichment equipment and methods have improved as experience and the understanding of atmospheric control and plant physiology have advanced. Plant metabolism and growth rate are dependent on the available atmospheric CO2. Plants are keenly sensitive to CO2 variations; optimum values must be constant and precisely controlled. The method, timing, and size of equipment must be properly determined to provide maximum benefits and economy. Carefully follow the operation charts to choose the proper size generator for the cubic foot area. Keep the recharge times to a minimum for best results. Do not undersize the generator or optimum results may never be achieved. Operates on 110 VAC.

     

    SKU:
    GACD6LP
    $540.00
  • CDDS-2 & CDM-6000 Monitor

    The CDMC-6 system is designed to sample the air and learn the characteristics of your space, then make adjustments as necessary to ensure a constant level of CO2. The CDM-6000 works in conjunction with the CDDS-2 controller (sequencer) to effectively enrich indoor gardens and greenhouses with CO2 or reconfigured the system mode to vent excess CO2 if desired.

    FEATURES

    • Built-in Photo Sensor for enhanced control
    • Easy to program and operate with adjustable hysteresis (differential)
    • Programmed for overshoot protection logic
    • Durable infrared sensor
    • CO2 measurement range from 0-5000 PPM
    • CO2 control range from 300-5000 PPM
    • Easy to read LED display light will not affect plant growth
    • Mode indicator LEDs
    • Factory calibrated and inspected for precision performance
    • Operates on 120 VAC at 60 Hz, 12 Amp switching capacity
    • Manufactured in Oregon, USA
    SKU:
    GACDMC6

    Retail: $859.95

    Special Price: $662.16

  • MCC-1 Microclimate Controller

    The Micro Climate Controller MCC-1 is designed to perform all the major atmospheric and timed functions required in an automated growth environment including temperature humidity carbon dioxide enrichment lighting and irrigation control. The controller incorporates an external coil cooling thermostat a dehumidifying humidistat a 24-hour clock timer a photo-sensor and a repeat cycle timer. Heating and humidifying control is provided by triggers for remote high-amperage relays which enable synchronized equipment management. Automatic override and defeat systems coordinate controls to consider all possible variables. The MCC-1 is enclosed in a black anodized brush finish aluminum housing. An attractive screen-printed front panel with function indicator lights makes system monitoring and adjustment quick and easy. All connections are standard 3-prong grounded plugs and receptacles. No hard wiring is required for basic operations. Low and high voltage relays are available to operate auxiliary equipment. Every aspect of the growing environment may be addressed by the Micro Climate Controller (MCC-1). Operates on 110VAC with 15 Amp switching capacity.Function Outlet Descriptions:Exhaust OutletThis outlet receives power when excess heat or humidity need to be ventilated. Intake and exhaust fans or other venting equipment can be automatically functioned according to the set-points on the thermostat and humidistat dial face. There is approximately five points differential between "On" and "Off" cycles to maintain a consistent air quality.CDDS-1 TriggerWhen using a CO2 monitor to determine and control CO2 producing equipment this outlet provides 24 hr. power which is defeated during exhaust functions to minimize CO2 loss. Plug CDMC-2 digital sequencer into this trigger to integrate CO2 management with atmospheric control.Timed OutletsThese outlets are operated by the 24 hr. time clock. Use to function almost any electrical equipment according to time of day settings. This precision synchronous clock provides 96 independent 15 min. On - Off trippers. Use the HAR-1 relay for high amperage or voltage equipment.HR-1 RelayThis feature provides power for heaters or heating relays. A small heater with built in thermostat can be plugged directly into HR-1 outlet. Larger units must use heating relay HR-1 to isolate high amperage requirements. Set heating thermostat to minimum allowable temperature and cooling thermostat to maximum high temperature. The span between these two settings is the comfort zone. The HR-1 relay outlet will not operate during exhaust functions.Cycle OutletThe cycle outlet utilizes the same internal short cycle timer and operates simultaneously with the CO2 outlet. When the photo sensor mode switch is in the cycle timer position the timer is not interrupted by the photo and exhaust defeat circuits. Both outlets will provide 24 hr. sequence timing for irrigation systems pumps solenoids transformers motors relays and many other equipment devices.CO2 OutletCarbon dioxide enrichment equipment can be precisely timed through this outlet by the on board cycle timer. This timer will repeat your pre-set "ON" and "Off" periods continuously whenever the photo sensor detects the presence of light. The duration of the "On" cycles are from 5 sec. to 30 min. and the frequency of "On" cycles ( or the "Off" time between them ) is from 7 min. to 8 hrs. The photo sensor mode switch must be in the CO2 timer position for photo and exhaust function defeat circuits. Reset feature will replenish CO2 immediately after exhaust cycle. Switch mode toggle to "Off" for manual reset.HF-1 RelayThis outlet is similar in function to the HR-1 relay outlet except it is for humidity producing apparatus. Humidifying equipment can not function during dehumidifying cycles.IMPORTANT:Make certain the combined amperage draw of all equipment operating through the MCC-1 does not exceed 15 amps. Use function relays to conduct high amperage or alternate voltage currents.
    SKU:
    GAMCC1

    Retail: $835.00

    Special Price: $584.50